Optimization and Validation of Microstrip Patch Antenna for Endoscopy Application

Juily Tarade, Uday Pandit Khot

2025

Abstract

Compared to standard endoscopy, wireless capsule endoscopy with non-invasive antennas has gained more attention. Since the transmitting antenna of a wireless capsule endoscope (WCE) is located inside the body as opposed to the receiving antenna, which is located outside of it, designing the transmitting antenna is a difficult challenge. Simultaneously achieving high data rates, small size, omni-directionality, acceptable specific absorption rate (SAR), and large bandwidth in telemetry systems are major hurdles faced by these antennas. This is because many parts of the gastrointestinal tract have different dielectric constants and thicknesses. To overcome these obstacles, antennas must be characterized for WCE. With a modified partial ground plane, the suggested antenna is a small planar slotted microstrip patch antenna. It is a miniature ingestion-capable Ultra-Wide Band (UWB) antenna. The substrate material for the antenna is Rogers TMM 13i. An environment that roughly represents the full human gastrointestinal (GI) tract, including surrounding tissues is created using the High Frequency Structure Simulator (HFSS 13.0). The performance of the antenna is evaluated by placing it in the middle of the various GI tracts. The suggested antenna's dimensions are 40 mm3 (10 mm × 10 mm × 0.4 mm) and is a mere 1.26 percent of the capsule's volume. About 4.3 GHz and 6.7 GHz, with a -3 dB bandwidth of about 20.4 MHz and 950 MHz, respectively, are the resonant frequencies. The advantage of having multiple resonant frequencies is that the proposed single antenna can be used for all the GI tract although the dielectric constant varies over the entire GI tract. The existing literature needs different antennas for different GI tracts. In the biological model, the radiation pattern is circularly polarized and omnidirectional. The maximum radiation efficiency of 95.65% has been observed. For the purpose of biocompatibility analysis, the SAR value in the GI tract is also calculated and is in well limit. Once patch is designed for endoscopy application, it needs to be validated which can be done with the help of link budget where AP > RP. To establish a stable communication link between the endoscopic antenna and external device, the antenna power (Ap) should be higher than the required power (Rp).

Download


Paper Citation


in Harvard Style

Tarade J. and Khot U. (2025). Optimization and Validation of Microstrip Patch Antenna for Endoscopy Application. In Proceedings of the 3rd International Conference on Futuristic Technology - Volume 3: INCOFT; ISBN 978-989-758-763-4, SciTePress, pages 197-205. DOI: 10.5220/0013611900004664


in Bibtex Style

@conference{incoft25,
author={Juily Tarade and Uday Khot},
title={Optimization and Validation of Microstrip Patch Antenna for Endoscopy Application},
booktitle={Proceedings of the 3rd International Conference on Futuristic Technology - Volume 3: INCOFT},
year={2025},
pages={197-205},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0013611900004664},
isbn={978-989-758-763-4},
}


in EndNote Style

TY - CONF

JO - Proceedings of the 3rd International Conference on Futuristic Technology - Volume 3: INCOFT
TI - Optimization and Validation of Microstrip Patch Antenna for Endoscopy Application
SN - 978-989-758-763-4
AU - Tarade J.
AU - Khot U.
PY - 2025
SP - 197
EP - 205
DO - 10.5220/0013611900004664
PB - SciTePress