processing, data acquisition and data 
communication. When applications, ground control 
part have a communication signals, to complete the 
collection of flow, temperature and pressure, and 
real-time display and control the down hole working 
conditions of the instruments, which can realize data 
admission control, data storage, report output and 
parameters tuning, etc. (as shown in figure 2). 
 
Figure 2: Structure diagram of ground control system. 
3.3 Straight-Reading Electric Measuring 
Instrument 
Straight-reading electric measuring instrument 
mainly by mechanical arm, the control part, 
measuring parts, steering mechanism and so on, by 
receiving the ground sends commands, adjusting 
arm, release and adjustable plug docking, flow 
testing adjustment, temperature, the stress state of 
measurement and testing is done at the same. And 
has the data signal modulation and demodulation 
and transmission function (as shown in figure 3). 
 
Figure 3: Physical drawing of the instrument. 
3.4 Adjustable Plugging Device 
The adjustable plug is the actuator of the straight-
reading electric measurement system, which is the 
core part of the whole system. It is divided into two 
types: adjustable partial pressure plug and adjustable 
molecular plug. 
3.4.1 Adjustable Partial Pressure Plug 
From the design points of polymer flooding process 
integration injection process pressure regulating 
elements, use of non-newtonian fluid mechanics 
theory and the flow field simulation software, 
optimize the pressure regulating element structure 
parameters, by adjusting the throttle element of 
effective length, control single injection pressure, 
achieves stepless adjustment of the first-level 
dispensing tool from low pressure loss to high 
pressure loss, to meet the needs of different 
injection. 
3.4.2 Adjustable Molecular Plug 
The existing separation technology adopts single 
water nozzle to adjust the molecular, and the 
adjustment range is less than 30% when the flow 
injection quantity (20-50m3/d) is lower, and when 
the injection scheme is changed, it needs to be put 
out the water mouth, which is cumbersome and 
inefficient. New type adjustable molecular plug by 
adjusting the number of nozzle to control the 
polymer solution degree of shear, to achieve high 
shear, low pressure loss, the continuous adjustable 
molecular weight, the injection of polymer 
molecular weight are best match of reservoir 
permeability, maximize the effective use of low 
permeable reservoirs. 
3.5  Cable Winch System 
To ensure the running of the measurement and 
control system, developed a special cable winch 
system, adopts the cylinder and the steel cable wire 
roller double drum structure, steel wire used for plug 
fishing, steel cable for test, two drum independent 
operation, common hydraulic drive system, 
operation convenient, flexible. The tension system 
shows the cable tension in the process, which is 
beneficial to construction operation and improve 
cable life. Winch uses two kinds of mechanical and 
electronic counting methods to realize 
complementary advantages and ensure the accuracy 
of depth. 
4 FIELD APPLICATION 
By the end of 2017, straight-reading electric 
measurement technology in the application of more 
than 300 Wells, 3-5 layer average single well test 
time reduced to 2.5 days from 5.2 days, measuring 
efficiency could be improved by more than 2 times. 
It can be seen from the comparison with 
conventional steel wire test, that the more the 
number of single Wells layer is divided, the more 
obvious the effect of electric measurement is, and