
REFERENCES 
Allen, P., Josephs, O., Turner, R., 2000. A method for 
removing imaging artifact from continuous EEG 
recorded during functional MRI. NeuroImage 12, 230-
239. 
Anami, K., Mori, T., Tanaka, F., Kawagoe, Y., Okamoto, 
J., Yarita, M., Ohnishi, T., Yumoto, M., Matsuda, H., 
Saitoh, O., 2003. Stepping stone sampling for 
retrieving artifact-free electroencephalogram during 
functional magnetic resonance imaging. NeuroImage 
19, 281–295. 
De Munck, J., Van Houdt, P., Gonçalves, S., Van Wegen, 
E., Ossenblok, P., 2013. Novel artefact removal 
algorithms for co-registered EEG/fMRI based on 
selective averaging and subtraction. NeuroImage 64, 
407-415. 
El-Tatar, A., Fokapu, O., 2011.  Modeling MR induced 
artifacts contaminating electrophysiological signals 
recorded during MRI. Proceedings of the 33
rd
 Annual 
International Conference of the IEEE EMBS 2011, 
Boston,  Massachusetts, August 30 – September 3, 
2011. 7135-7138. 
Ferreira, J., Cluitmans, P., Aarts, R.M., 2012. Gradient 
artefact correction in the EEG signal recorded within 
the fMRI scanner. Proceedings of the 5
th
 International 
Conference on Bio-inspired Systems and Signal 
Processing, BIOSIGNALS 2012, Vilamoura, Portugal, 
February 1 – 4, 2012. 110-117. 
Ferreira, J., Cluitmans, P., Aarts, R.M., 2013a. Gradient 
artefact modelling using a set of sinusoidal waveforms 
for EEG correction during continuous fMRI. Signal 
Processing Research 2, 39-48. 
Ferreira, J., Cluitmans, P., Aarts, R.M., 2013b. Non-linear 
filter for gradient artefact correction during 
simultaneous EEG-fMRI. Signal Processing Research 
2, 55-63. 
Ferreira, J., Cluitmans, P., Aarts, R.M., 2013c. Detection 
of sharp wave activity in biological signals using 
differentiation between consecutive samples. 
Proceedings of the  6
th
 International Conference on 
Bio-inspired Systems and Signal Processing, 
BIOSIGNALS 2013, Barcelona, Spain, February 11 – 
14, 2013. 327-332. 
Fritsch, F., Carlson, R., 1980. Monotone piecewise cubic 
interpolation. SIAM. J. Numer. Anal. 17, 238-246. 
Garreffa, G., Carnì, M., Gualniera, G., Ricci, G.B., 
Bozzao, L., De Carli, D., Morasso, P., Pantano, P., 
Colonnese, C., Roma, V., Maraviglia, B., 2003. Real-
time MR artifacts filtering during continuous 
EEG/fMRI acquisition. Magn. Res. Imaging. 21, 1175-
1189. 
Gonçalves, S., Pouwels, P., Kuijer, J., Heethaar, R., De 
Munck, J., 2007. Artifact removal in co-registered 
EEG/fMRI by selective average subtraction. Clin. 
Neurophysiol. 118, 823-838. 
Koskinen, M., Vartiainen, N., 2009. Removal of imaging 
artifacts in EEG during simultaneous EEG/fMRI 
recording: reconstruction of a high-precision artifact 
template. NeuroImage 46, 160-167. 
Kreyszig, E., 2011. Advanced engineering mathematics. 
10
th
 e. Wiley: New York. 
Moosmann, M., Schönfelder, V., Specht, K., Scheeringa, 
R., Nordby, H., Hugdahl, K., 2009. Realignment 
parameter-informed artefact correction for 
simultaneous EEG-fMRI recordings. NeuroImage  45, 
1144-1150. 
Niazy, R., Beckmann, C., Iannetti, G., Brady, J., Smith, S., 
2005. Removal of FMRI environment artifacts from 
EEG data using optimal basis sets. NeuroImage 28, 
720-737. 
Olson, W., 2010. Basic concepts of medical 
instrumentation. In J. Webster (ed.), Medical 
instrumentation: application and design. 4
th
 ed. Wiley: 
New York. 
Ritter, P., Becker, R., Freyer, F., Villringer, A., 2010. EEG 
quality: the image acquisition artifact. In C. Mulert, L. 
Limieux (eds.), EEG-fMRI: Physiological basis, 
technique and applications. Springer: Verlag, Berlin, 
Heidelberg. 
Sun, L., Hinrichs, H., 2009. Simultaneously recorded 
EEG-fMRI: removal of gradient artifacts by 
subtraction of head movement related average artifact 
waveforms. Hum. Brain Mapp. 30, 3361–3377. 
Van Liempt, S., Vermetten, E., Lentjes, E., Arends, J., 
Westenberg, H., 2011. Decreased nocturnal growth 
hormone secretion and sleep fragmentation in combat-
related posttraumatic stress disorder; potential 
predictors of impaired memory consolidation. 
Psychoneuroendocrino. 36, 1361-1369. 
Wolberg, G., Alfy, I., 1999. Monotonic cubic spline 
interpolation.  Proceedings of the  Computer Graphics 
International Conference, CGI 1999, Canmore, 
Canada, June 7 – 11, 1999. 188-195. 
Yan, W., Mullinger, K., Brookes, M., Bowtell, R., 2009. 
Understanding gradient artefacts in simultaneous 
EEG/fMRI. NeuroImage 46, 459-471. 
BIOSIGNALS2014-InternationalConferenceonBio-inspiredSystemsandSignalProcessing
220