loading
Papers

Research.Publish.Connect.

Paper

Paper Unlock

Authors: A. Sieber 1 ; K. Houston 2 ; A. Menciassi 2 ; G. Nauer 3 and P. Dario 2

Affiliations: 1 Profactor Research and Solutions GmbH; Scuola Superiore Sant’Anna, Italy ; 2 Scuola Superiore Sant’Anna, Italy ; 3 ECHEM, Austria

ISBN: 978-989-8111- 17-3

Keyword(s): Fetal surgery, Endoscopy, Fetoscopy, Pulmonary Atresia, Bio-impedance, Catheter.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instrumentation ; Biomedical Instruments and Devices ; Electrical Bio-Impedance

Abstract: Pulmonary Atresia is a malfunction that is diagnosed in about 1 out of 20.000 fetus. The authors propose a novel surgical intervention where the fetal heart is accessed with an endoscopic intervention through the umbilical cord. The key for this innovative procedure is a novel micro-catheter that is equipped with sensor and actuators that allow active navigation inside the heart and also tissue characterisation. The present paper presents the first prototype.

PDF ImageFull Text

Download
CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 34.204.173.36

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Sieber A.; Houston K.; Menciassi A.; Nauer G.; Dario P. and (2008). SENSORIZED MICROCATHETER - Smart Microinstrumentation Adressing Fetal Surgery – First Results.In Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 2: BIODEVICES, (BIOSTEC 2008) ISBN 978-989-8111- 17-3, pages 190-195. DOI: 10.5220/0001047301900195

@conference{biodevices08,
author={A. Sieber and K. Houston and A. Menciassi and G. Nauer and P. Dario},
title={SENSORIZED MICROCATHETER - Smart Microinstrumentation Adressing Fetal Surgery – First Results},
booktitle={Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 2: BIODEVICES, (BIOSTEC 2008)},
year={2008},
pages={190-195},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001047301900195},
isbn={978-989-8111- 17-3},
}

TY - CONF

JO - Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 2: BIODEVICES, (BIOSTEC 2008)
TI - SENSORIZED MICROCATHETER - Smart Microinstrumentation Adressing Fetal Surgery – First Results
SN - 978-989-8111- 17-3
AU - Sieber, A.
AU - Houston, K.
AU - Menciassi, A.
AU - Nauer, G.
AU - Dario, P.
PY - 2008
SP - 190
EP - 195
DO - 10.5220/0001047301900195

Login or register to post comments.