loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: A. Sieber 1 ; K. Houston 2 ; A. Menciassi 2 ; G. Nauer 3 and P. Dario 2

Affiliations: 1 Profactor Research and Solutions GmbH; Scuola Superiore Sant’Anna, Italy ; 2 Scuola Superiore Sant’Anna, Italy ; 3 ECHEM, Austria

Keyword(s): Fetal surgery, Endoscopy, Fetoscopy, Pulmonary Atresia, Bio-impedance, Catheter.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instrumentation ; Biomedical Instruments and Devices ; Electrical Bio-Impedance

Abstract: Pulmonary Atresia is a malfunction that is diagnosed in about 1 out of 20.000 fetus. The authors propose a novel surgical intervention where the fetal heart is accessed with an endoscopic intervention through the umbilical cord. The key for this innovative procedure is a novel micro-catheter that is equipped with sensor and actuators that allow active navigation inside the heart and also tissue characterisation. The present paper presents the first prototype.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.14.70.203

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Sieber, A.; Houston, K.; Menciassi, A.; Nauer, G. and Dario, P. (2008). SENSORIZED MICROCATHETER - Smart Microinstrumentation Adressing Fetal Surgery – First Results. In Proceedings of the First International Conference on Biomedical Electronics and Devices (BIOSTEC 2008) - Volume 2: BIODEVICES; ISBN 978-989-8111- 17-3; ISSN 2184-4305, SciTePress, pages 190-195. DOI: 10.5220/0001047301900195

@conference{biodevices08,
author={A. Sieber. and K. Houston. and A. Menciassi. and G. Nauer. and P. Dario.},
title={SENSORIZED MICROCATHETER - Smart Microinstrumentation Adressing Fetal Surgery – First Results},
booktitle={Proceedings of the First International Conference on Biomedical Electronics and Devices (BIOSTEC 2008) - Volume 2: BIODEVICES},
year={2008},
pages={190-195},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001047301900195},
isbn={978-989-8111- 17-3},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the First International Conference on Biomedical Electronics and Devices (BIOSTEC 2008) - Volume 2: BIODEVICES
TI - SENSORIZED MICROCATHETER - Smart Microinstrumentation Adressing Fetal Surgery – First Results
SN - 978-989-8111- 17-3
IS - 2184-4305
AU - Sieber, A.
AU - Houston, K.
AU - Menciassi, A.
AU - Nauer, G.
AU - Dario, P.
PY - 2008
SP - 190
EP - 195
DO - 10.5220/0001047301900195
PB - SciTePress