loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Mattia Dimitri 1 ; Fabio Staderini 2 ; Sara Aquino 1 ; Lucrezia Mazzantini 1 ; Andrea Corvi 1 and Guido Biffi Gentili 3

Affiliations: 1 Department of Industrial Engineering, University of Florence, via di Santa Marta 3, Florence, Italy ; 2 Department of Experimental and Clinical Medicine, University of Florence, S. Marco Square 4, Florence, Italy ; 3 Department of Information Engineering, University of Florence, via di Santa Marta 3, Florence, Italy

Keyword(s): Perfusion, Ex-vivo, Liver, Thermal Ablation, Microwave.

Abstract: The paper compares thermal ablation on perfused and not perfused porcine liver produced by 17 and 14 Gauge non internally cooled (NIC) microwave (MW) applicators. To the knowledge of the authors this comparison, already made using cooled applicators has not so far been carried out with uncooled applicators that have a very different thermo-kinetic behavior when they operate inside a biological tissue. The purpose of this preliminary study is to explore the possibility of using ex vivo perfused liver in order to define an optimal protocol to allow more reliable translation of the experiments to the clinical practice and compare the obtained results with those of previous studies that used similar energy delivery.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.222.125.171

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Dimitri, M.; Staderini, F.; Aquino, S.; Mazzantini, L.; Corvi, A. and Gentili, G. (2020). Comparison of Ex-vivo Perfused and Non-perfused Porcine Liver Ablations using Uncooled Microwave Applicators. In Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - BIODEVICES; ISBN 978-989-758-398-8; ISSN 2184-4305, SciTePress, pages 118-123. DOI: 10.5220/0008947501180123

@conference{biodevices20,
author={Mattia Dimitri. and Fabio Staderini. and Sara Aquino. and Lucrezia Mazzantini. and Andrea Corvi. and Guido Biffi Gentili.},
title={Comparison of Ex-vivo Perfused and Non-perfused Porcine Liver Ablations using Uncooled Microwave Applicators},
booktitle={Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - BIODEVICES},
year={2020},
pages={118-123},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0008947501180123},
isbn={978-989-758-398-8},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - BIODEVICES
TI - Comparison of Ex-vivo Perfused and Non-perfused Porcine Liver Ablations using Uncooled Microwave Applicators
SN - 978-989-758-398-8
IS - 2184-4305
AU - Dimitri, M.
AU - Staderini, F.
AU - Aquino, S.
AU - Mazzantini, L.
AU - Corvi, A.
AU - Gentili, G.
PY - 2020
SP - 118
EP - 123
DO - 10.5220/0008947501180123
PB - SciTePress