loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: K. Charrière 1 ; A. Guitton 2 ; V. Ratié 3 ; L. Sighi-Dumoulin 3 ; V. Bourcier 4 ; P. Morel 3 ; L. Pazart 1 and B. Wacogne 1 ; 2

Affiliations: 1 Centre Hospitalier Universitaire de Besançon, Centre d’Investigation Clinique, INSERM CIC 1431, 25030, Besançon, France ; 2 FEMTO-ST Institute, Univ. Bourgogne Franche-Comte, CNRS, 15B avenue des Montboucons, 25030 Besancon, cedex, France ; 3 Etablissement Français du Sang Bourgogne/Franche-Comté, 25000 Besançon, France ; 4 Haemovigilance Service, Besançon University Hospital, 25000 Besançon, France

Keyword(s): Crossmatch, Human Red Blood Cells, Fluorescence, Biochip, Immuno-detection.

Abstract: One of the most feared transfusion accident is the haemolytic reaction. A majority of countries imposes a compatibility test before each transfusion, at the patient’s bedside or in laboratory. Regardless of the test performed, it does not prevent human errors and nothing ensures an “error free” procedure. Complete crossmatch is the only test ensuring a complete blood compatibility between donors and patients. It relies on the direct or indirect detection of agglutinations which occur when the patient’s plasma is mixed with the red cells to be transfused. It requires extracting plasma. The work described here will help avoid all the immunologic incompatibilities by the use of a compatibility test without plasma extraction. It relies on an immuno-biochip technology in a microfluidic environment with fluorescence detection. This position paper presents preliminary results obtained with artificial samples together with comments on the state of industrial competition and the new device ma rket positioning. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 13.58.39.23

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Charrière, K.; Guitton, A.; Ratié, V.; Sighi-Dumoulin, L.; Bourcier, V.; Morel, P.; Pazart, L. and Wacogne, B. (2019). Blood-to-blood Immunological Compatibility Test: A Possibility with Fluorescent Immuno-Biochips. In Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2019) - BIODEVICES; ISBN 978-989-758-353-7; ISSN 2184-4305, SciTePress, pages 160-166. DOI: 10.5220/0007356001600166

@conference{biodevices19,
author={K. Charrière. and A. Guitton. and V. Ratié. and L. Sighi{-}Dumoulin. and V. Bourcier. and P. Morel. and L. Pazart. and B. Wacogne.},
title={Blood-to-blood Immunological Compatibility Test: A Possibility with Fluorescent Immuno-Biochips},
booktitle={Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2019) - BIODEVICES},
year={2019},
pages={160-166},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0007356001600166},
isbn={978-989-758-353-7},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2019) - BIODEVICES
TI - Blood-to-blood Immunological Compatibility Test: A Possibility with Fluorescent Immuno-Biochips
SN - 978-989-758-353-7
IS - 2184-4305
AU - Charrière, K.
AU - Guitton, A.
AU - Ratié, V.
AU - Sighi-Dumoulin, L.
AU - Bourcier, V.
AU - Morel, P.
AU - Pazart, L.
AU - Wacogne, B.
PY - 2019
SP - 160
EP - 166
DO - 10.5220/0007356001600166
PB - SciTePress