loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: A. Sieber 1 ; R. Bedini 2 ; X. Yong 3 ; A. Navarri 2 ; M. Dalle Luche 2 ; A. L’Abbate 4 and P. Dario 4

Affiliations: 1 Profactor Research and Solutions GmbH; Scuola Superiore Sant’ Anna, Italy ; 2 CNR, Istituto di Fisiologia Clinica, Italy ; 3 MEMS Center of Chongqing University, China ; 4 Scuola Superiore Sant’ Anna, Italy

Keyword(s): ECG, breath-hold, apnoe, diving, PQ interval.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Equipment ; Biomedical Instrumentation ; Biomedical Instruments and Devices

Abstract: Breath hold diving induces several physiological effects. The authors speculate that next to bradycardia, vasoconstriction, splenic contraction and blood shift, the form of the ECG and especially the PQ interval are also affected. Investigations of this effect requires a high resolution ECG monitor which is also capable of recording depth. This paper describes our data logger prototype. It samples ECG data at 1200 Hz, is equipped with three temperature and a pressure sensor that allows depth measurement up to 140 m and stores all the data in an ASCII text file on a SD flash card in FAT 16 or FAT32 file format. The prototype is then encapsulated in a Lexan tube with an outer diameter of 42 mm and an overall length of 18cm that should withstand 20 bar pressure equal to 200 m depth.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.142.196.27

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Sieber, A.; Bedini, R.; Yong, X.; Navarri, A.; Dalle Luche, M.; L’Abbate, A. and Dario, P. (2008). HIGH RESOLUTION ECG AND DEPTH DATA LOGGER - A Novel Device to Study Breath Hold Diving Induced Variations of the PQ Interval. In Proceedings of the First International Conference on Biomedical Electronics and Devices (BIOSTEC 2008) - Volume 1: BIODEVICES; ISBN 978-989-8111- 17-3; ISSN 2184-4305, SciTePress, pages 269-275. DOI: 10.5220/0001052102690275

@conference{biodevices08,
author={A. Sieber. and R. Bedini. and X. Yong. and A. Navarri. and M. {Dalle Luche}. and A. L’Abbate. and P. Dario.},
title={HIGH RESOLUTION ECG AND DEPTH DATA LOGGER - A Novel Device to Study Breath Hold Diving Induced Variations of the PQ Interval},
booktitle={Proceedings of the First International Conference on Biomedical Electronics and Devices (BIOSTEC 2008) - Volume 1: BIODEVICES},
year={2008},
pages={269-275},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001052102690275},
isbn={978-989-8111- 17-3},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the First International Conference on Biomedical Electronics and Devices (BIOSTEC 2008) - Volume 1: BIODEVICES
TI - HIGH RESOLUTION ECG AND DEPTH DATA LOGGER - A Novel Device to Study Breath Hold Diving Induced Variations of the PQ Interval
SN - 978-989-8111- 17-3
IS - 2184-4305
AU - Sieber, A.
AU - Bedini, R.
AU - Yong, X.
AU - Navarri, A.
AU - Dalle Luche, M.
AU - L’Abbate, A.
AU - Dario, P.
PY - 2008
SP - 269
EP - 275
DO - 10.5220/0001052102690275
PB - SciTePress