Abstract: Although a number of laser Doppler blood flow sensors have been developed over the past few decades, they remain uncommon in practice. This is because the contact pressure between the skin and the sensor is not measured simultaneously with blood flow, despite the fact that blood flow is greatly affected by contact pressure. Thus, reliable and highly reproducible measurement of blood flow could not yet be realized. In addition, changes in beam conditions or body temperature also have an effect on blood flow measurement. Therefore, we fabricated a micro electro mechanical system (MEMS) blood flow sensor which can measure contact pressure, beam power, and body temperature, for reliable and highly reproducible measurement.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.223.119.17

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Inoue, R.; Nogami, H.; Higurashi, E. and Sawada, R. (2018). Simultaneous Measurement of a Blood Flow and a Contact Pressure . In Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - BIOSIGNALS; ISBN 978-989-758-279-0; ISSN 2184-4305, SciTePress, pages 48-53. DOI: 10.5220/0006596800480053

@conference{biosignals18,
author={Ryo Inoue. and Hirofumi Nogami. and Eiji Higurashi. and Renshi Sawada.},
title={Simultaneous Measurement of a Blood Flow and a Contact Pressure },
booktitle={Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - BIOSIGNALS},
year={2018},
pages={48-53},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006596800480053},
isbn={978-989-758-279-0},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - BIOSIGNALS
TI - Simultaneous Measurement of a Blood Flow and a Contact Pressure
SN - 978-989-758-279-0
IS - 2184-4305
AU - Inoue, R.
AU - Nogami, H.
AU - Higurashi, E.
AU - Sawada, R.
PY - 2018
SP - 48
EP - 53
DO - 10.5220/0006596800480053
PB - SciTePress