Authors: Mohamed Elgendi ; Mirjam Jonkman and Friso DeBoer

Affiliation: Charles Darwin University, Australia

ISBN: 978-989-674-018-4

Keyword(s): Heart Rate, HRV, Plethysmography, SDPTG.

Related Ontology Subjects/Areas/Topics: Applications and Services ; Artificial Intelligence ; Biomedical Engineering ; Biomedical Signal Processing ; Computer Vision, Visualization and Computer Graphics ; Data Manipulation ; Health Engineering and Technology Applications ; Human-Computer Interaction ; Medical Image Detection, Acquisition, Analysis and Processing ; Methodologies and Methods ; Neurocomputing ; Neurotechnology, Electronics and Informatics ; Pattern Recognition ; Physiological Computing Systems ; Real-Time Systems ; Sensor Networks ; Soft Computing

Abstract: Heart-rate monitoring is a basic measure for cardiovascular functionality assessment. The electrocardiogram (ECG) and Holter monitoring devices are accurate, but their use in the field is limited. Photoplethysmography is an optical technique that has been developed for experimental use in vascular disease. Because of its non-invasive, safe, and easy-to-use properties, it is considered a promising tool that may replace some of the current traditional cardiovascular diagnostic tools. A useful algorithm for a-wave detection in the second derivative plethysmogram (SDPTG) is introduced for heart–rate monitoring. The performance of the proposed method was tested on 27 records measured at rest and after exercise. Statistical HRV measures can be calculated using the a-a interval of the SDPTG.

PDF ImageFull Text

Download
CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 34.204.173.45

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Elgendi M.; Jonkman M.; DeBoer F. and (2010). HEART RATE VARIABILITY MEASUREMENT USING THE SECOND DERIVATIVE PHOTOPLETHYSMOGRAM.In Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010) ISBN 978-989-674-018-4, pages 82-87. DOI: 10.5220/0002743300820087

@conference{biosignals10,
author={Mohamed Elgendi and Mirjam Jonkman and Friso DeBoer},
title={HEART RATE VARIABILITY MEASUREMENT USING THE SECOND DERIVATIVE PHOTOPLETHYSMOGRAM},
booktitle={Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)},
year={2010},
pages={82-87},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002743300820087},
isbn={978-989-674-018-4},
}

TY - CONF

JO - Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)
TI - HEART RATE VARIABILITY MEASUREMENT USING THE SECOND DERIVATIVE PHOTOPLETHYSMOGRAM
SN - 978-989-674-018-4
AU - Elgendi, M.
AU - Jonkman, M.
AU - DeBoer, F.
PY - 2010
SP - 82
EP - 87
DO - 10.5220/0002743300820087