Authors: Evgeny G. Vaschillo 1 ; Bronya Vaschillo 2 ; Jennifer F. Buckman 2 ; Marsha E. Bates 2 and Robert J. Pandina 2

Affiliations: 1 Rutgers, the State University of New Jersey, United States ; 2 Rutgers,The State University of New Jersey, United States

ISBN: 978-989-674-018-4

Keyword(s): Baroreflex, Closed-loop control system, Resonance frequency, HRV biofeedback.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Signal Processing ; Physiological Processes and Bio-Signal Modeling, Non-Linear Dynamics

Abstract: The baroreflex, as a control system with negative feedback, is a mechanism that buffers changes in blood pressure (BP), thereby precluding strong, abrupt shifts in arterial pressure. As a closed-loop control system with delays, the baroreflex possesses resonance features at frequencies of about 0.1 and 0.03 Hz. These resonance frequencies correspond to a ~5-s delay in the BP response to changes in heart rate (HR) (HR baroreflex closed-loop) and a ~15-s delay in the vascular tone (VT) response to changes in BP (VT baroreflex closed-loop). Thus, whereas a single impact on the cardiovascular system (CVS) elicits a HR, BP, and VT oscillatory response that fades over time, 0.1 or 0.03 Hz rhythmical stimulation of the CVS produces steady HR, BP, and VT oscillations with significantly higher amplitudes comparing to stimulation at other frequencies. Resonances in the baroreflex system are essential for the maintenance of optimal health by keeping autonomic regulation active via HR, BP, and VT variability, providing adaptive responses to internal and external stimuli, and buffering stress and emotional reactivity via inhibitory effect in the brain. This study investigates the phenomenon of resonances in the CVS and the ability to employ these resonances for clinical applications. (More)

PDF ImageFull Text

Download
CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.207.137.4

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
G. Vaschillo E.; Vaschillo B.; F. Buckman J.; E. Bates M.; J. Pandina R. and (2010). RESONANCES IN THE CARDIOVASCULAR SYSTEM - Investigation and Clinical Applications.In Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010) ISBN 978-989-674-018-4, pages 21-28. DOI: 10.5220/0002691200210028

@conference{biosignals10,
author={Evgeny {G. Vaschillo} and Bronya Vaschillo and Jennifer {F. Buckman} and Marsha {E. Bates} and Robert {J. Pandina}},
title={RESONANCES IN THE CARDIOVASCULAR SYSTEM - Investigation and Clinical Applications},
booktitle={Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)},
year={2010},
pages={21-28},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002691200210028},
isbn={978-989-674-018-4},
}

TY - CONF

JO - Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)
TI - RESONANCES IN THE CARDIOVASCULAR SYSTEM - Investigation and Clinical Applications
SN - 978-989-674-018-4
AU - G. Vaschillo, E.
AU - Vaschillo, B.
AU - F. Buckman, J.
AU - E. Bates, M.
AU - J. Pandina, R.
PY - 2010
SP - 21
EP - 28
DO - 10.5220/0002691200210028