loading
Papers

Research.Publish.Connect.

Paper

Paper Unlock

Authors: A. Temko ; I. Korotchikova ; W. Marnane ; G. Lightbody and G. Boylan

Affiliation: University College Cork, Ireland

ISBN: 978-989-674-018-4

Keyword(s): Neonatal, Seizure, Detection, Automated, Energy, Normalization, Support vector machines, Healthy patients, False detections per hour.

Related Ontology Subjects/Areas/Topics: Applications and Services ; Artificial Intelligence ; Biomedical Engineering ; Biomedical Signal Processing ; Computer Vision, Visualization and Computer Graphics ; Data Manipulation ; Health Engineering and Technology Applications ; Human-Computer Interaction ; Medical Image Detection, Acquisition, Analysis and Processing ; Methodologies and Methods ; Neurocomputing ; Neurotechnology, Electronics and Informatics ; Pattern Recognition ; Physiological Computing Systems ; Sensor Networks ; Soft Computing

Abstract: Seizures in newborn babies are commonly caused by problems such as lack of oxygen, haemorrhage, meningitis, infection and strokes. The aim of an automated neonatal seizure detection system is to assist clinical staff in a neonatal intensive care unit to interpret the EEG. In this work, the automated neonatal seizure detection system is validated on a set of healthy patients and its performance is compared to the performance obtained on sick patients reported previously. The histogram-based energy normalization technique is designed and applied to EEG signals from healthy patients to cope with montage mismatch. The results on healthy babies compares favourably to those obtained on sick babies. Several useful observations are made which were not possible to obtain by testing on sick babies only such as a practically useful range of probabilistic thresholds, minimum detection duration restriction, and an influence of the database statistics on the system performance.

PDF ImageFull Text

Download
CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 34.239.160.113

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Temko A.; Korotchikova I.; Marnane W.; Lightbody G.; Boylan G. and (2010). VALIDATION OF AN AUTOMATED SEIZURE DETECTION SYSTEM ON HEALTHY BABIES - Histogram-based Energy Normalization for Montage Mismatch Compensation.In Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010) ISBN 978-989-674-018-4, pages 312-317. DOI: 10.5220/0002750303120317

@conference{biosignals10,
author={A. Temko and I. Korotchikova and W. Marnane and G. Lightbody and G. Boylan},
title={VALIDATION OF AN AUTOMATED SEIZURE DETECTION SYSTEM ON HEALTHY BABIES - Histogram-based Energy Normalization for Montage Mismatch Compensation},
booktitle={Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)},
year={2010},
pages={312-317},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002750303120317},
isbn={978-989-674-018-4},
}

TY - CONF

JO - Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)
TI - VALIDATION OF AN AUTOMATED SEIZURE DETECTION SYSTEM ON HEALTHY BABIES - Histogram-based Energy Normalization for Montage Mismatch Compensation
SN - 978-989-674-018-4
AU - Temko, A.
AU - Korotchikova, I.
AU - Marnane, W.
AU - Lightbody, G.
AU - Boylan, G.
PY - 2010
SP - 312
EP - 317
DO - 10.5220/0002750303120317

Login or register to post comments.