loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: H. C. Pereira 1 ; J. B. Simoes 1 ; J. L. Malaquias 1 ; T. Pereira 2 ; V. Almeida 2 ; E. Borges 2 ; J. Cardoso 2 and C. Correia 2

Affiliations: 1 ISA – Intelligent Sensing Anywhere; University of Coimbra, Portugal ; 2 University of Coimbra, Portugal

Keyword(s): Local Pulse Wave Velocity, Double Headed Probe, Piezoelectric Sensor, Test Bench, Impulse Response.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instrumentation ; Biomedical Instruments and Devices ; Biomedical Sensors

Abstract: The present work proposes a new device for local pulse wave velocity (PWV), by using an innovative configuration of a double piezoelectric (PZ) sensor probe. PWV is assessed in one single location and involves the determination of time delay, between the signals acquired simultaneously by two PZs, 23 mm apart. The double probe (DP) is characterized in a dedicated test bench system, where two main studies were carried out. In the first one, the impulse response (IR) for each PZ sensor is determined and evaluated through the deconvolution method. In the second one, DP time resolution is estimated from a set of time delay algorithms and compared with the reference values, obtained through the signals of two pressure sensors. Results demonstrate the effectiveness of the inferred IRs in deconvolution purposes and the possibility of measure higher PWV values (≈ 19m/s), through the DP, with an error less than 10%.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.191.236.174

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Pereira, H.; Simoes, J.; Malaquias, J.; Pereira, T.; Almeida, V.; Borges, E.; Cardoso, J. and Correia, C. (2011). DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2011) - BIODEVICES; ISBN 978-989-8425-37-9; ISSN 2184-4305, SciTePress, pages 444-447. DOI: 10.5220/0003293704440447

@conference{biodevices11,
author={H. C. Pereira. and J. B. Simoes. and J. L. Malaquias. and T. Pereira. and V. Almeida. and E. Borges. and J. Cardoso. and C. Correia.},
title={DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2011) - BIODEVICES},
year={2011},
pages={444-447},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003293704440447},
isbn={978-989-8425-37-9},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2011) - BIODEVICES
TI - DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment
SN - 978-989-8425-37-9
IS - 2184-4305
AU - Pereira, H.
AU - Simoes, J.
AU - Malaquias, J.
AU - Pereira, T.
AU - Almeida, V.
AU - Borges, E.
AU - Cardoso, J.
AU - Correia, C.
PY - 2011
SP - 444
EP - 447
DO - 10.5220/0003293704440447
PB - SciTePress