loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: T. Pereira 1 ; M. Cabeleira 1 ; P. Matos 1 ; E. Borges 1 ; V. Almeida 1 ; J. Cardoso 1 ; C. Correia 1 and H. C. Pereira 2

Affiliations: 1 University of Coimbra, Portugal ; 2 University of Coimbra; ISA- Intelligent Sensing Anywhere, Portugal

Keyword(s): Optical probes, Photodiode, Waveform distension, Pulse Transit Time, Pulse Wave Velocity.

Related Ontology Subjects/Areas/Topics: Applications and Services ; Biomedical Engineering ; Biomedical Signal Processing ; Cardiovascular Signals ; Computer Vision, Visualization and Computer Graphics ; Medical Image Detection, Acquisition, Analysis and Processing

Abstract: Pulse wave velocity (PWV) is a clinically interesting parameter associated to cardiac risk due to arterial stiffness, generally evaluated by the time that the pressure wave spends to travel between two arbitrary points. Optic sensors are an attractive instrumental solution in this kind of time assessment applications due to their truly non-contact operation capability, which ensures an interference free measurement. On the other hand, they can pose different challenges to the designer, mostly related to the features of the signals they produce and to the associated signal processing burden required to extract error free, reliable information. In this work we evaluate two prototype optical probes dedicated to pulse transit time (PTT) evaluation as well as three algorithms for its assessment. Although the tests were carried out at the test bench, where “well behaved” signals can be obtained, the transition to a probe for use in humans is also considered. Results demonstrated the possib ility of measuring pulse transit times as short as 1 ms with less than 1% error. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.117.148.105

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Pereira, T.; Cabeleira, M.; Matos, P.; Borges, E.; Almeida, V.; Cardoso, J.; Correia, C. and C. Pereira, H. (2011). OPTICAL METHODS FOR LOCAL PULSE WAVE VELOCITY ASSESSMENT. In Proceedings of the International Conference on Bio-inspired Systems and Signal Processing (BIOSTEC 2011) - BIOSIGNALS; ISBN 978-989-8425-35-5; ISSN 2184-4305, SciTePress, pages 74-81. DOI: 10.5220/0003166800740081

@conference{biosignals11,
author={T. Pereira. and M. Cabeleira. and P. Matos. and E. Borges. and V. Almeida. and J. Cardoso. and C. Correia. and H. {C. Pereira}.},
title={OPTICAL METHODS FOR LOCAL PULSE WAVE VELOCITY ASSESSMENT},
booktitle={Proceedings of the International Conference on Bio-inspired Systems and Signal Processing (BIOSTEC 2011) - BIOSIGNALS},
year={2011},
pages={74-81},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003166800740081},
isbn={978-989-8425-35-5},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Bio-inspired Systems and Signal Processing (BIOSTEC 2011) - BIOSIGNALS
TI - OPTICAL METHODS FOR LOCAL PULSE WAVE VELOCITY ASSESSMENT
SN - 978-989-8425-35-5
IS - 2184-4305
AU - Pereira, T.
AU - Cabeleira, M.
AU - Matos, P.
AU - Borges, E.
AU - Almeida, V.
AU - Cardoso, J.
AU - Correia, C.
AU - C. Pereira, H.
PY - 2011
SP - 74
EP - 81
DO - 10.5220/0003166800740081
PB - SciTePress