loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: O. Abdallah 1 ; Q. Qananwah 1 ; A. Bolz 1 ; J. Hansmann 2 ; S. Hinderer 2 and H. Mertsching 2

Affiliations: 1 Institute of Biomedical Engineering IBT and Karlsruhe Institute of Technology KIT, Germany ; 2 Fraunhofer Institute for Interfacial Engineering and Biotechnology IGB and University of Stuttgart, Germany

Keyword(s): Fluorescence, Biosensors, Non-invasive glucose concentration monitoring, High signal to noise ratio, Fluorescence spectroscopy, Glucose management, LASER for detection of glucose concentration.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Equipment ; Biomedical Instrumentation ; Biomedical Instruments and Devices ; Biomedical Sensors ; Devices ; Health Monitoring Devices ; Human-Computer Interaction ; Physiological Computing Systems

Abstract: An easy accessible and low-cost method for glucose concentration monitoring and diabetes management will be a great help for more than 250 millions of diabetic patients worldwide to avoid the risks and the complications caused by hyper- or hypoglycemia. This paper shows the results obtained using fluorescence spectroscopy for detecting the glucose concentrations in DMEM solutions. By irradiating DMEM solutions that have different glucose concentrations with light, a few wavelengths in UV- and visible-range for the calculations of glucose concentrations using fluorescence spectroscopy are applied and the detected signals were analyzed. For the detection of glucose concentration noninvasively using various optical methods, the interaction between light and definite glucose solutions was studied. The developed compact system will enable the application of different LASER diodes (LD`s) or light emitting diodes (LED`s) in the range of UV and NIR in an easy manner. Variable intensity, fre quency and duty cycle can be adjusted for fluorescence and other optical measurements. A multi-sensor taking all perturbations into account will be a good choice for glucose monitoring. Fluorescence measurements at wavelengths below 800 nm and especially the measurements at the wavelength 485 nm give reproducible glucose concentrations results from DMEM glucose solutions at a constant temperature. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.217.144.32

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Abdallah, O.; Qananwah, Q.; Bolz, A.; Hansmann, J.; Hinderer, S. and Mertsching, H. (2011). FLUORESCENCE SPECTROSCOPY BY DETECTION OF GLUCOSE CONCENTRATIONS IN DMEM-SOLUTIONS AND ITS PERSPECTIVES FOR NON-INVASIVE MEASUREMENT. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2011) - BIODEVICES; ISBN 978-989-8425-37-9; ISSN 2184-4305, SciTePress, pages 411-414. DOI: 10.5220/0003176504110414

@conference{biodevices11,
author={O. Abdallah. and Q. Qananwah. and A. Bolz. and J. Hansmann. and S. Hinderer. and H. Mertsching.},
title={FLUORESCENCE SPECTROSCOPY BY DETECTION OF GLUCOSE CONCENTRATIONS IN DMEM-SOLUTIONS AND ITS PERSPECTIVES FOR NON-INVASIVE MEASUREMENT},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2011) - BIODEVICES},
year={2011},
pages={411-414},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003176504110414},
isbn={978-989-8425-37-9},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2011) - BIODEVICES
TI - FLUORESCENCE SPECTROSCOPY BY DETECTION OF GLUCOSE CONCENTRATIONS IN DMEM-SOLUTIONS AND ITS PERSPECTIVES FOR NON-INVASIVE MEASUREMENT
SN - 978-989-8425-37-9
IS - 2184-4305
AU - Abdallah, O.
AU - Qananwah, Q.
AU - Bolz, A.
AU - Hansmann, J.
AU - Hinderer, S.
AU - Mertsching, H.
PY - 2011
SP - 411
EP - 414
DO - 10.5220/0003176504110414
PB - SciTePress