loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Andrzej Dyszkiewicz 1 ; Paweł Połeć 2 ; Jakub Zajdel 2 ; Bartłomiej Pawlus 3 ; Damian Chachulski 2 and Paweł Kpiński 2

Affiliations: 1 Technical University of Opole, Poland ; 2 Laboratory of Biotechnology, Poland ; 3 Specialist Rehabilitation Department ”VIS”, Poland

Keyword(s): Incoherence x-ray beam, Collimation of x-ray beam, Ferrofluids, Computer steering.

Abstract: The study addressed the problem of the incoherence of an X-ray tube generated bundle. In spite of the large progress made in the area of the durability and efficiency of these devices, the problem of the inherent divergence of the bundle hasnt yet been resolved in a satisfying way. In the face of difficulties with concentrating X-rays, the only practical way of eliminating non-axial rays is by applying lead collimators of a suitable length and diameter as well as mechanical systems of movable distracting grids. An entirely new approach has been the use of electro-magnetorheological fluids as filters, which are capable of modifying their physical and quantum properties contingently based on the parameters of the applied external electric current, centrifugal force and magnetic field. The experiments carried out showed, that the described changes also concern the absorbtion, distraction or change in the direction of the X-ray beam. In the constructed prototype device, interesting and r ecurrent results in the modification or eleimination of non-axial rays were obtained, which resulted in the improvement of the quality of bone images. The following research questions were posed: (1) are changes in the photodensitometric parameters of joint (PIP) X-ray images containing soft and osseous tissues proof of alterations of the physical parameters of a diagnostic X-ray beam? (2) is there a relationship between the volume of ferrofluid in a lens and its capability to alter the parameters of a permeating X-ray beam? (3) is there a relationship between the r.p.m. of the collimator and its capability to alter the parameters of a permeating X-ray beam, and does it have a linear character? Based on the conducted research a non-linear dependancy was observed between the volume of ferrofluid in the lens as well as its rotational speed and the capability of the system to alter the parameters of the permeating X-ray beam. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.145.191.22

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Dyszkiewicz, A.; Połeć, P.; Zajdel, J.; Pawlus, B.; Chachulski, D. and Kpiński, P. (2009). COLLIMATION OF X-RAY DIAGNOSTIC BUNDLE BY MEANS OF STEERING FERROFLUID. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2009) - Special Session AMMD; ISBN 978-989-8111- 64-7; ISSN 2184-4305, SciTePress, pages 441-447. DOI: 10.5220/0001817704410447

@conference{special session ammd09,
author={Andrzej Dyszkiewicz. and Paweł Połeć. and Jakub Zajdel. and Bartłomiej Pawlus. and Damian Chachulski. and Paweł Kpiński.},
title={COLLIMATION OF X-RAY DIAGNOSTIC BUNDLE BY MEANS OF STEERING FERROFLUID},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2009) - Special Session AMMD},
year={2009},
pages={441-447},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001817704410447},
isbn={978-989-8111- 64-7},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2009) - Special Session AMMD
TI - COLLIMATION OF X-RAY DIAGNOSTIC BUNDLE BY MEANS OF STEERING FERROFLUID
SN - 978-989-8111- 64-7
IS - 2184-4305
AU - Dyszkiewicz, A.
AU - Połeć, P.
AU - Zajdel, J.
AU - Pawlus, B.
AU - Chachulski, D.
AU - Kpiński, P.
PY - 2009
SP - 441
EP - 447
DO - 10.5220/0001817704410447
PB - SciTePress