loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: A. Martínez-Olmos ; A. J. Palma ; J. Ballesta-Claver ; M. C. Valencia-Miron and L. F. Capitan-Vallvey

Affiliation: University of Granada, Spain

Keyword(s): Electrochemiluminescence, Portable instrumentation, Potentiostat, Biosensor, Screen-printed device, Lactate determination, Saliva.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instrumentation ; Biomedical Instruments and Devices ; Biomedical Sensors ; Low-Power Design

Abstract: A new hand-held luminometer for electrochemiluminescence (ECL)-based one-shot biosensor for lactate is described. The lactate recognition system is based on lactate oxidase and the transduction system consists of luminol, all reagents immobilized in a Methocel membrane. The measurement of ECL from a screenprinted electrode by a portable instrument designed and developed by the authors makes it possible to determine lactate concentration. The compositions of the membrane and reaction conditions have been optimized to obtain adequate sensitivity. The one-shot biosensor responds to lactate rapidly, with the typical ECL acquisition time being 3 min, with a linearized dependence whose dynamic range was from 9·10-6 to 2·10-3 M, a detection limit of 2.4·10-6 M and a sensor-to-sensor reproducibility (relative standard deviation RSD) around 10 % at the medium level of the range. The performance of the ECL one-shot biosensor and portable instrument was tested for the non invasive analysis of l actate in saliva, validating the results against a reference procedure. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.119.131.178

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Martínez-Olmos, A.; J. Palma, A.; Ballesta-Claver, J.; C. Valencia-Miron, M. and F. Capitan-Vallvey, L. (2009). HAND-HELD LUMINOMETER WITH ECL-BASED BIOSENSOR FOR LACTATE DETERMINATION. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2009) - BIODEVICES; ISBN 978-989-8111- 64-7; ISSN 2184-4305, SciTePress, pages 343-346. DOI: 10.5220/0001432703430346

@conference{biodevices09,
author={A. Martínez{-}Olmos. and A. {J. Palma}. and J. Ballesta{-}Claver. and M. {C. Valencia{-}Miron}. and L. {F. Capitan{-}Vallvey}.},
title={HAND-HELD LUMINOMETER WITH ECL-BASED BIOSENSOR FOR LACTATE DETERMINATION},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2009) - BIODEVICES},
year={2009},
pages={343-346},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001432703430346},
isbn={978-989-8111- 64-7},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2009) - BIODEVICES
TI - HAND-HELD LUMINOMETER WITH ECL-BASED BIOSENSOR FOR LACTATE DETERMINATION
SN - 978-989-8111- 64-7
IS - 2184-4305
AU - Martínez-Olmos, A.
AU - J. Palma, A.
AU - Ballesta-Claver, J.
AU - C. Valencia-Miron, M.
AU - F. Capitan-Vallvey, L.
PY - 2009
SP - 343
EP - 346
DO - 10.5220/0001432703430346
PB - SciTePress