loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Hanne O. Austad ; Jon Vedum ; Morten H. Røed ; Steffen Dalgard ; Tomas Brødreskift ; Anders E. Liverud ; Frode Strisland and Trine M. Seeberg

Affiliation: SINTEF-Informatics and Communication Technology, Norway

Keyword(s): Wearable Sensor, Blood Pressure, Pulse Transit Time, ICG, PPG.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instrumentation ; Biomedical Instruments and Devices ; Biomedical Sensors ; Devices ; Electrocardiography and Heart Monitoring ; Health Monitoring Devices ; Human-Computer Interaction ; Physiological Computing Systems ; Technologies Evaluation

Abstract: There is a clinical need for improved ambulatory, frequent and unobtrusive monitoring of blood pressure and cardiac parameters like systolic time intervals. Truly unobtrusive wearable devices combining impedance cardiography with other sensors may be one possible solution. The IsenseU-BP+ device presented in this article measures single channel ECG, impedance cardiography and photo plethysmography at the chest. The device also measures activity and posture, as well as skin temperature. In this study, we report on the possibility to use these signals to measure pulse transit time for estimating blood pressure changes. Six subjects has been tested. Four of them showed good correlation between PTT and mean arterial pressure while two of the subjects had too low signal to noise ratio in the photoplethysmography signal for good estimation of PTT. Thus these results show that the quality of the raw data is promising for calculating a pulse transit time that shows good coherence with mean a rterial pressure. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 35.171.164.77

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Austad, H.; Vedum, J.; Røed, M.; Dalgard, S.; Brødreskift, T.; Liverud, A.; Strisland, F. and Seeberg, T. (2016). An Unobtrusive Wearable Device for Ambulatory Monitoring of Pulse Transit Time to Estimate Central Blood Pressure. In Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2016) - BIODEVICES; ISBN 978-989-758-170-0; ISSN 2184-4305, SciTePress, pages 179-186. DOI: 10.5220/0005701401790186

@conference{biodevices16,
author={Hanne O. Austad. and Jon Vedum. and Morten H. Røed. and Steffen Dalgard. and Tomas Brødreskift. and Anders E. Liverud. and Frode Strisland. and Trine M. Seeberg.},
title={An Unobtrusive Wearable Device for Ambulatory Monitoring of Pulse Transit Time to Estimate Central Blood Pressure},
booktitle={Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2016) - BIODEVICES},
year={2016},
pages={179-186},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005701401790186},
isbn={978-989-758-170-0},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2016) - BIODEVICES
TI - An Unobtrusive Wearable Device for Ambulatory Monitoring of Pulse Transit Time to Estimate Central Blood Pressure
SN - 978-989-758-170-0
IS - 2184-4305
AU - Austad, H.
AU - Vedum, J.
AU - Røed, M.
AU - Dalgard, S.
AU - Brødreskift, T.
AU - Liverud, A.
AU - Strisland, F.
AU - Seeberg, T.
PY - 2016
SP - 179
EP - 186
DO - 10.5220/0005701401790186
PB - SciTePress