Authors: Giovanni Saggio 1 ; Arnaldo D'Amico 1 ; Vito Errico 1 ; Giovanni Costantini 1 ; Giorgio Pennazza 2 ; Alessandro Zompanti 2 and Marco Santonico 2

Affiliations: 1 University of Rome Tor Vergata, Italy ; 2 Campus Bio-Medico University of Rome, Italy

Keyword(s): Resistive Flex Sensor, Humidity Sensor, Humidity Sensitivity, Sensitivity.

Abstract: During last decades, a number of different sensors have been developing for different analytics to detect. A key aspect of those sensors is that each of them results with a fixed particular sensitivity. Consequently, at occurrence, it is necessary to use a plurality of sensors to arrange measures with different levels of sensitivity. This work intends to investigate the possibility to obtain different sensitivity, in particular with respect to humidity, from one sensor only. To this aim we investigated the resistive flex sensor, which has been already used for other applications but, as far as we know, never investigated for its potential properties as a chemical sensor. Results demonstrated how the resistive flex sensor behaves with different sensitivity values and different sensitivity curves for different bend conditions.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 44.192.67.10

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Saggio, G.; D'Amico, A.; Errico, V.; Costantini, G.; Pennazza, G.; Zompanti, A. and Santonico, M. (2018). A Sensor Which Can Be Varied in Humidity Sensitivity. In Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - BIOSIGNALS; ISBN 978-989-758-279-0; ISSN 2184-4305, SciTePress, pages 113-118. DOI: 10.5220/0006546001130118

@conference{biosignals18,
author={Giovanni Saggio. and Arnaldo D'Amico. and Vito Errico. and Giovanni Costantini. and Giorgio Pennazza. and Alessandro Zompanti. and Marco Santonico.},
title={A Sensor Which Can Be Varied in Humidity Sensitivity},
booktitle={Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - BIOSIGNALS},
year={2018},
pages={113-118},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006546001130118},
isbn={978-989-758-279-0},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2018) - BIOSIGNALS
TI - A Sensor Which Can Be Varied in Humidity Sensitivity
SN - 978-989-758-279-0
IS - 2184-4305
AU - Saggio, G.
AU - D'Amico, A.
AU - Errico, V.
AU - Costantini, G.
AU - Pennazza, G.
AU - Zompanti, A.
AU - Santonico, M.
PY - 2018
SP - 113
EP - 118
DO - 10.5220/0006546001130118
PB - SciTePress