loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Sarah Rosen 1 ; Carole A. Tucker 2 and Rahamim Seliktar 3

Affiliations: 1 Shriners Hospitals for Children, United States ; 2 Temple University, United States ; 3 Drexel University, United States

Keyword(s): Gait Forces, Gait Cycle, Gait Impulse, Gait Consistency, Pediatric Gait.

Abstract: The “gait cycle” is considered the fundamental repetitive element of locomotion and is often used in comparative analyses between pathological and normal gait. One device that is used to measure ground reaction forces in the gait laboratory is a six degrees of freedom force transducer (“Force Plate”). Gait labs use two or more force plates to measure forces during one or two complete strides. Often, the walker “aims” to step sequentially on the force plates. This aiming may cause significant distortion of the person’s gait pattern. To validate the measured result as representative of the individual’s gait, a “Gait Consistency Test” was developed by Seliktar et.al with a group of adult individuals. The present study employed the consistency test to the ground reaction force records of two groups of children; typically developing children and children with cerebral palsy. The children’s gait consistency study yielded even better results than the adult study; the results showed that the consistency test is useful for screening children’s gait data and should be used to ensure higher fidelity of the measured data. The test applied equally to normally developing children and to children with gait pathologies. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 44.200.210.43

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Rosen, S.; A. Tucker, C. and Seliktar, R. (2014). Forceplates Data Reliability Tested on Children with Neuromuscular Disabilities. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - TPDULL; ISBN 978-989-758-013-0; ISSN 2184-4305, SciTePress, pages 303-306. DOI: 10.5220/0004934303030306

@conference{tpdull14,
author={Sarah Rosen. and Carole {A. Tucker}. and Rahamim Seliktar.},
title={Forceplates Data Reliability Tested on Children with Neuromuscular Disabilities},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - TPDULL},
year={2014},
pages={303-306},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004934303030306},
isbn={978-989-758-013-0},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - TPDULL
TI - Forceplates Data Reliability Tested on Children with Neuromuscular Disabilities
SN - 978-989-758-013-0
IS - 2184-4305
AU - Rosen, S.
AU - A. Tucker, C.
AU - Seliktar, R.
PY - 2014
SP - 303
EP - 306
DO - 10.5220/0004934303030306
PB - SciTePress