Authors: Roberto L. Avitia 1 ; Marco A. Reyna 1 ; Miguel E. Bravo 1 and Lucio A. Cetto 2

Affiliations: 1 Bioengineering Academic Body, University Autonomous of Baja California, Mexico ; 2 The MathWorks, Inc., United States

ISBN: 978-989-674-017-7

Keyword(s): Signal averaged electrocardiography, Dynamic programming, Piecewise linear approximation, Heartbeat alignment.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instruments and Devices ; Biomedical Metrology

Abstract: Signal Averaged Electrocardiography (SAECG) is a technique widely used as an alternative to improve signal to noise ratio (SNR), but sometimes patient’s physiology may alter the characteristics of quasi-steady heartbeats that are assumed in the averaging. This paper evaluates the noise as a parameter for measuring the alignment heartbeats by Derivative Dynamic Time Warping (DDTW) and using Piecewise Linear Approximation (PLA) as well. The records were taken from a group of healthy individuals and the results show that the number of heartbeats averaged necessary to improve the SNR is less than the traditional method.

PDF ImageFull Text

Download
Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 54.198.246.164

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
L. Avitia R.; A. Reyna M.; E. Bravo M.; A. Cetto L. and (2010). SIGNAL TO NOISE RATIO EVALUATION IN SIGNAL AVERAGED ECG BY DERIVATIVE DYNAMIC TIME WARPING AND PIECEWISE LINEAR APPROXIMATION .In Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010) ISBN 978-989-674-017-7, pages 201-205. DOI: 10.5220/0002748802010205

@conference{biodevices10,
author={Roberto {L. Avitia} and Marco {A. Reyna} and Miguel {E. Bravo} and Lucio {A. Cetto}},
title={SIGNAL TO NOISE RATIO EVALUATION IN SIGNAL AVERAGED ECG BY DERIVATIVE DYNAMIC TIME WARPING AND PIECEWISE LINEAR APPROXIMATION },
booktitle={Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010)},
year={2010},
pages={201-205},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002748802010205},
isbn={978-989-674-017-7},
}

TY - CONF

JO - Proceedings of the Third International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2010)
TI - SIGNAL TO NOISE RATIO EVALUATION IN SIGNAL AVERAGED ECG BY DERIVATIVE DYNAMIC TIME WARPING AND PIECEWISE LINEAR APPROXIMATION
SN - 978-989-674-017-7
AU - L. Avitia, R.
AU - A. Reyna, M.
AU - E. Bravo, M.
AU - A. Cetto, L.
PY - 2010
SP - 201
EP - 205
DO - 10.5220/0002748802010205