Authors: Weijun Mi 1 ; Haiwen Chen 2 and Wenfeng Fu 3

Affiliations: 1 Shaanxi Xin Yuan Clean Energy Co.Ltd., China ; 2 School of Energy, Power and Mechanical Engineering, North China Electric Power University, China ; 3 North China Electric Power University, Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, China

Keyword(s): double reheat, fuel specific consumption, outer steam coolers

Abstract: Taking the 1000MW double reheat ultra-supercritical unit as an example, based on analysis of the specific fuel consumption, the effects of following arrangement modes of outer steam cooler (OSC) on the energy consumption of unit are studied, such as the single series arrangement, double series arrangement and double parallel arrangement, etc., and subsequently the optimum arrangement mode of OSCs is obtained, in which case the variation law of specific fuel consumption is analyzed for each part of the thermal system and for the whole unit. Results show that by adopting the OSCs, the feed water temperature is raised, the irreversible loss of boiler is reduced, thus lowering the specific fuel consumption of unit. In the single arrangement mode, the specific fuel consumption can be reduced by 0.632g/kWh at most when the OSC is arranged at No.2 high pressure (HP) regenerative heater (RH);whereas in the double arrangement mode, the specific fuel consumption can be reduced by 1.122g/kWh at most when the coolers are arranged in series at RH2 and RH4. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.238.228.191

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Mi, W.; Chen, H. and Fu, W. (2018). A Study on the Arrangement of Outer Steam Cooler for 1000MW Double Reheat Ultra-Supercritical Unit. In 3rd International Conference on Electromechanical Control Technology and Transportation - ICECTT; ISBN 978-989-758-312-4, SciTePress, pages 59-62. DOI: 10.5220/0006964900590062

@conference{icectt18,
author={Weijun Mi. and Haiwen Chen. and Wenfeng Fu.},
title={A Study on the Arrangement of Outer Steam Cooler for 1000MW Double Reheat Ultra-Supercritical Unit},
booktitle={3rd International Conference on Electromechanical Control Technology and Transportation - ICECTT},
year={2018},
pages={59-62},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006964900590062},
isbn={978-989-758-312-4},
}

TY - CONF

JO - 3rd International Conference on Electromechanical Control Technology and Transportation - ICECTT
TI - A Study on the Arrangement of Outer Steam Cooler for 1000MW Double Reheat Ultra-Supercritical Unit
SN - 978-989-758-312-4
AU - Mi, W.
AU - Chen, H.
AU - Fu, W.
PY - 2018
SP - 59
EP - 62
DO - 10.5220/0006964900590062
PB - SciTePress