loading
Papers

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Julija Razumiene ; Ieva Sakinyte ; Tatjana Kochane ; Sandra Maciulyte ; Antanas Straksys ; Saulute Budriene and Jurgis Barkauskas

Affiliation: Vilnius University, Lithuania

ISBN: 978-989-8565-34-1

Keyword(s): Urea Biosensor, Modified Graphite, Polymeric Carrier, Enzyme, Amperometry.

Related Ontology Subjects/Areas/Topics: Biomaterials ; Biomedical Engineering ; Biomedical Instruments and Devices

Abstract: The amperometric biosensor for urea determination was designed based on the electrochemical oxidation of urea decomposition products produced by urease. The enzyme electrode, made of a specially developed modified graphite (MG) paste, was produced by covering the electrode surface with new polymeric carriers poly(urethane-urea) (PUU) microparticles containing immobilized urease from Canavalia ensiformis (E.C. 3.5.1.5.).

PDF ImageFull Text

Download
CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.233.219.101

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Razumiene, J.; Sakinyte, I.; Kochane, T.; Maciulyte, S.; Straksys, A.; Budriene, S. and Barkauskas, J. (2013). Carbon Electrode based Urea Sensor - Modification of Graphite and New Polymeric Carriers for Enzyme Immobilization.In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2013) ISBN 978-989-8565-34-1, pages 197-201. DOI: 10.5220/0004326901970201

@conference{biodevices13,
author={Julija Razumiene. and Ieva Sakinyte. and Tatjana Kochane. and Sandra Maciulyte. and Antanas Straksys. and Saulute Budriene. and Jurgis Barkauskas.},
title={Carbon Electrode based Urea Sensor - Modification of Graphite and New Polymeric Carriers for Enzyme Immobilization},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2013)},
year={2013},
pages={197-201},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004326901970201},
isbn={978-989-8565-34-1},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2013)
TI - Carbon Electrode based Urea Sensor - Modification of Graphite and New Polymeric Carriers for Enzyme Immobilization
SN - 978-989-8565-34-1
AU - Razumiene, J.
AU - Sakinyte, I.
AU - Kochane, T.
AU - Maciulyte, S.
AU - Straksys, A.
AU - Budriene, S.
AU - Barkauskas, J.
PY - 2013
SP - 197
EP - 201
DO - 10.5220/0004326901970201

Login or register to post comments.