INVESTIGATION OF OPERATING PARAMETERS FOR A SEMEN QUALITY ANALYSIS SYSTEM

S. Atherton, C. R. Evans, P. Roach, D. C. Hughes, G. McHale, M. I. Newton

2009

Abstract

To increase the success rate of Artificial Insemination (AI) in animals, it is important that the semen sample is of a high quality. The quality is related to both the number and motility of sperm present. Numerous methods of analysing semen samples exist, but these are generally expensive and/or laboratory based. A useful alternative would be an inexpensive simple system that could be used in the field immediately prior to insemination. We present a time of flight (ToF) technique using a quartz crystal microbalance (QCM). In this system the sperm are introduced at one end of a liquid filled swim channel and self propel to a QCM sensor at the other end. A chemical coating is applied to the QCM to bind the sperm and from the frequency change the number of attached sperm and their ToF can be measured. We report the effect of temperature and the introduction of small quantities of progesterone into the swim channel on the sperm ToF. Results show the QCM can be used to detect the arrival of the sperm and that increasing temperature and the presence of progesterone are both shown to decrease the ToF.

References

  1. Mortimer, S. T., 2000, CASA - Practical Aspects, J.ournal Andrology, 21, p.515-524
  2. Christensen, P., Boelling, D., Pedersen, K. M., Korsgaard, I. R., & Jensen, J., 2005, Journal of Andrology, 26
  3. Sauerbrey, G., 1959, Zeitschrift für Physik, p.155-206
  4. Da Silva, L. B., Trebes, J. E., Balhorn, R., Mrowaka, S., Anderson, E., Attwood, D. T., Barbee, T. W., Brase, J., Corzett, M., Gray, J., Koch, J. A., Lee, C., Kern, D., London, R. A., MacGowan, B. J., Matthews, D. L., & Stone, G., 1992, X-ray laser microscopy of rat sperm nuclei, Science, 258, p.269-271
  5. Kanazawa, K., & Gordon, J. G., 1985, Frequency of a Quartz Crystal Microbalance in contact with a liquid, Journal of Analytical Chemistry, 57, p.1770-1771
  6. Newton, M. I., Evans, C. R., Simons, J. J., & Hughes, D. C., 2007, Semen quality detection using time of flight and acoustic wave sensors, Applied Physics Letters 90(15)
Download


Paper Citation


in Harvard Style

Atherton S., R. Evans C., Roach P., C. Hughes D., McHale G. and I. Newton M. (2009). INVESTIGATION OF OPERATING PARAMETERS FOR A SEMEN QUALITY ANALYSIS SYSTEM . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 13-16. DOI: 10.5220/0001429600130016


in Bibtex Style

@conference{biodevices09,
author={S. Atherton and C. R. Evans and P. Roach and D. C. Hughes and G. McHale and M. I. Newton},
title={INVESTIGATION OF OPERATING PARAMETERS FOR A SEMEN QUALITY ANALYSIS SYSTEM},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={13-16},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001429600130016},
isbn={978-989-8111- 64-7},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - INVESTIGATION OF OPERATING PARAMETERS FOR A SEMEN QUALITY ANALYSIS SYSTEM
SN - 978-989-8111- 64-7
AU - Atherton S.
AU - R. Evans C.
AU - Roach P.
AU - C. Hughes D.
AU - McHale G.
AU - I. Newton M.
PY - 2009
SP - 13
EP - 16
DO - 10.5220/0001429600130016