MULTIPARAMETER SINGLE LOCUS INTEGRATED MULTILAYER POLYMER MICROSENSOR SYSTEM

Yindar Chuo, Bozena Kaminska

2008

Abstract

Miniaturization and microintegration is well known for their potentials in providing microsystems and sensors with unmatched performance, reliability, and lower costs. Current technologies in implementation of microsensors, however, span a large variety of platforms. It is thus common for microsensors measuring differing parameters to exist on different combinations of substrates, not to even mention the associated signal conditioning, processing, and data communication electronics. It remains a challenge to integrate multiple sensors with complex electronics into a single high-density microsystem, particularly for certain applications in medical diagnostics and healthcare, where mechanical flexibility of the substrate and biocompatibility also becomes crucial considerations. Traditional microintegration technologies such as system-in-package, system-on-chip, and advanced assembly and packaging, may often be inadequate. A mutliparameter single locus integrated multilayer polymer microsensor system is proposed to address the fundamental issues of high-density integration, flexibility, biocompatibility, easy application, high sensitivity, and reliability for medical grade diagnostics and other physiological applications. The architecture of the multilayer system is discussed, as well, implementation and fabrication of the multisensor layer is demonstrated, and the results on performance discussed.

Download


Paper Citation


in Harvard Style

Chuo Y. and Kaminska B. (2008). MULTIPARAMETER SINGLE LOCUS INTEGRATED MULTILAYER POLYMER MICROSENSOR SYSTEM . In Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2008) ISBN 978-989-8111- 17-3, pages 36-43. DOI: 10.5220/0001047200360043


in Bibtex Style

@conference{biodevices08,
author={Yindar Chuo and Bozena Kaminska},
title={MULTIPARAMETER SINGLE LOCUS INTEGRATED MULTILAYER POLYMER MICROSENSOR SYSTEM},
booktitle={Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2008)},
year={2008},
pages={36-43},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001047200360043},
isbn={978-989-8111- 17-3},
}


in EndNote Style

TY - CONF
JO - Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2008)
TI - MULTIPARAMETER SINGLE LOCUS INTEGRATED MULTILAYER POLYMER MICROSENSOR SYSTEM
SN - 978-989-8111- 17-3
AU - Chuo Y.
AU - Kaminska B.
PY - 2008
SP - 36
EP - 43
DO - 10.5220/0001047200360043