In the research of neural diseases like epilepsy and schizophrenia genetic mouse models play a very important role. Dysfunctions during early brain development might cause these diseases. The analysis of the brain signals is the key to understand this process and develop treatments. To enable the acquisition of brain signals from neonatal mice, an integrated circuit for neural recording is presented. It is minimized for low area consumption and can be placed in a miniaturized system on the head of the mouse. It is intended to acquire the local field and action potentials from the brain. 16 analog input channels are implemented. The biomedical signals are amplified with analog pre-amplifiers. Two parallel structures of 8:1 multiplexer, post-amplifier and ADC are implemented to digitize the signals. The post-amplifier has programmable gain and high driving capability. The ADC is implemented as a 10 bit SAR ADC. Digital SPI interfacing is used to reduce the number of transmission lines. Reed Solomon Error Correction Coding has been implemented to enable error correction. The mixed-signal integrated circuit has been successfully implemented in a 130 nm CMOS technology. It is optimized for low area consumption; the channel density is approximately 10 channels/mm².

References

  1. Bahr A., Abu-Saleh L., Schroeder D., Krautschneider W. 2015 Development of a Neural Recording Mixed Signal Integrated Circuit for Biomedical Signal Acquisition In: Biomedical Engineering: Abstracts BMT 2015 Vol. 60 Issue: S1, pp. 298-299.
  2. Ben-Ari Y., Khazipov R., Leinekugel X., Caillard O., Gaiarsa J.L. 1997 GABAA, NMDA and AMPA receptors: a developmentally regulated “ménage à trois.” In Trends in Neurosciences 20:523-529.
  3. Harrison, R. R., Charles, C. 2003 A Low-Power LowNoise CMOS Amplifier for Neural Recording Applications. In IEEE Journal of Solid-State Circuits, Vol. 38, No. 6, pp. 958 - 965.
  4. NeuroNexus, 2013 Research Products Catalog, In: NeuroNexus Technologies, Inc. Research Products Catalog Vol. 3, Ver. 2, p. 60.
  5. Lewis D. A., Levitt P. 2002 Schizophrenia as a disorder of neurodevelopment. In: Annual review of neuroscience 25:409-32.
  6. Tej, P.R. and Jhansi Rani, K. (2013) VHDL Implementation of Reed Solomon Improved Encoding Algorithm In IJR-CCT, 2(7):435-439).
  7. Tomasik, J. M., Hafkemeyer, K. M., Galjan, W. , Schroeder, D., Krautschneider, W. H., 17.-18. Nov. 2008 A 130 nm CMOS Programmable Operational Amplifier. In Norchip 2008, Tallinn, Estonia.
Download


Paper Citation


in Harvard Style

Bahr A., Saleh L., Schroeder D. and Krautschneider W. (2016). Integrated 16-Channel Neural Recording Circuit with SPI Interface and Error Correction Code in 130Nm CMOS Technology . In Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2016) ISBN 978-989-758-170-0, pages 263-268. DOI: 10.5220/0005820402630268


in Bibtex Style

@conference{biodevices16,
author={Andreas Bahr and Lait Abu Saleh and Dietmar Schroeder and Wolfgang Krautschneider},
title={Integrated 16-Channel Neural Recording Circuit with SPI Interface and Error Correction Code in 130Nm CMOS Technology},
booktitle={Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2016)},
year={2016},
pages={263-268},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005820402630268},
isbn={978-989-758-170-0},
}


in EndNote Style

TY - CONF
JO - Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2016)
TI - Integrated 16-Channel Neural Recording Circuit with SPI Interface and Error Correction Code in 130Nm CMOS Technology
SN - 978-989-758-170-0
AU - Bahr A.
AU - Saleh L.
AU - Schroeder D.
AU - Krautschneider W.
PY - 2016
SP - 263
EP - 268
DO - 10.5220/0005820402630268