SILICON-BASED GOLD TRANSDUCERS FOR DNA BIOSENSORS

Łukasz Górski, Robert Ziółkowski, Elżbieta Malinowska, Piotr Prokaryn, Michał Zaborowski

2011

Abstract

Silicon-based chips with vacuum deposited gold electrode were tested as transducers for the development of DNA-modified biosensors. It was found that these structures are superior over commercially available transducers, mainly due to perfectly smooth surface of gold working electrode. This was confirmed with microscopic and electrochemical experiments. Obtained transducers were modified with oligonucleotide self-assembled monolayer. These sensors were shown to detect chosen DNA sequence with the employment of methylene blue as a redox marker. The same sensors were used to determine UO22+ cation, however these efforts were unsuccessful.

References

  1. Luong, J. H. T., Male, K. B., Glennon, J. D., 2008. Biosensor technology: Technology push versus market pull. In Biotechnol. Adv.
  2. Andreescu, S., Sadik O. A., 2004. Trends and challenges in biochemical sensors for clinical and environmental monitoring. In Pure Appl. Chem.
  3. Wang, J., 2000. Analytical electrochemistry, Wiley-VCH. New York, 2nd edition.
  4. Hianik, T., Wang, J., 2009. Electrochemical Aptasensors - Recent Achievements and Perspectives. In Electroanalysis.
  5. Erdem, A., Ozsoz, M., 2002. Electrochemical DNA Biosensors Based on DNA-Drug Interactions. In Electroanalysis.
  6. Ziolkowski, R., Gorski, L., Zaborowski, M., Malinowska, E., 2010. Application of mass fabricated silicon-based gold transducers for amperometric biosensors. In Bioelectrochemistry.
  7. Kelley, S.O., Barton, J. K., Jackson, N. M., Hill, M. G., 1997. Electrochemistry of Methylene Blue Bound to a DNA-Modified Electrode. In Bioconjugate Chem.
  8. Yazzie, M., Gamble, S. L., Civitello, E. R., Stearns D. M., 2003. Uranyl Acetate Causes DNA Single Strand Breaks In Vitro in the Presence of Ascorbate (Vitamin C). In Chem. Res. Toxicol.
Download


Paper Citation


in Harvard Style

Górski Ł., Ziółkowski R., Malinowska E., Prokaryn P. and Zaborowski M. (2011). SILICON-BASED GOLD TRANSDUCERS FOR DNA BIOSENSORS . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011) ISBN 978-989-8425-37-9, pages 146-149. DOI: 10.5220/0003133901460149


in Bibtex Style

@conference{biodevices11,
author={Łukasz Górski and Robert Ziółkowski and Elżbieta Malinowska and Piotr Prokaryn and Michał Zaborowski},
title={SILICON-BASED GOLD TRANSDUCERS FOR DNA BIOSENSORS},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)},
year={2011},
pages={146-149},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003133901460149},
isbn={978-989-8425-37-9},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)
TI - SILICON-BASED GOLD TRANSDUCERS FOR DNA BIOSENSORS
SN - 978-989-8425-37-9
AU - Górski Ł.
AU - Ziółkowski R.
AU - Malinowska E.
AU - Prokaryn P.
AU - Zaborowski M.
PY - 2011
SP - 146
EP - 149
DO - 10.5220/0003133901460149