CONTACT LESS RADIO-FREQUENCIES BIOSENSOR FOR BIOLOGICAL PARAMETERS ANALYSIS

K. Grenier, D. Dubuc, M. Kumemura, H. Toshiyoshi, H. Fujita

2009

Abstract

This paper presents a biosensor, which both takes benefits from RF/microwave detection scheme for contactless ability and from microtechnologies fabrication potentialities for massive integration of sensors into lab on chip. The proposed sensor is based on transmission line (which is the basis element of numerous microwave circuits) associated with a biological micro volume in interaction with electrical microwave fields. Thanks to the transmission characteristic of the line, we then detect the presence of DNA inside its nominal liquid environment with a measured sensitivity compatible with RF/microwave measurements capabilities. The results then demonstrated the potentialities of this approach for the analysis of biological parameters of ‘in vitro’ biological substance using microsystem integration facilities.

References

  1. Bashir, R., 2004. Advanced Drug Delivery Reviews, 56 Buchner, R., Barthel, J., Stauber, J., 1999. Chemical Physics Letters 306, 57-63
  2. Gabriel, S., Lau, R. W., Gabriel, C., 1996. Phys. Med. Biol. 41, 2251-2269
  3. Jiang, J. H., Wu, D. L., 2004. Atmos. Sci. Let. 5: 146-151 Khan, U., & al., 2007. IEEE Int. Microwave Symp., June Liu, C., Pu, Y., 2008. IEEE Microwave and Wireless Components Letters, Vol. 18, n°4, April
  4. Sebastian, 2004. IEEE European Microwave Conference
Download


Paper Citation


in Harvard Style

Grenier K., Dubuc D., Kumemura M., Toshiyoshi H. and Fujita H. (2009). CONTACT LESS RADIO-FREQUENCIES BIOSENSOR FOR BIOLOGICAL PARAMETERS ANALYSIS . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 398-401. DOI: 10.5220/0001547603980401


in Bibtex Style

@conference{biodevices09,
author={K. Grenier and D. Dubuc and M. Kumemura and H. Toshiyoshi and H. Fujita},
title={CONTACT LESS RADIO-FREQUENCIES BIOSENSOR FOR BIOLOGICAL PARAMETERS ANALYSIS},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={398-401},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001547603980401},
isbn={978-989-8111- 64-7},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - CONTACT LESS RADIO-FREQUENCIES BIOSENSOR FOR BIOLOGICAL PARAMETERS ANALYSIS
SN - 978-989-8111- 64-7
AU - Grenier K.
AU - Dubuc D.
AU - Kumemura M.
AU - Toshiyoshi H.
AU - Fujita H.
PY - 2009
SP - 398
EP - 401
DO - 10.5220/0001547603980401