loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: José L. Ferreira 1 ; Ronald M. Aarts 2 and Pierre J. M. Cluitmans 3

Affiliations: 1 Eindhoven University of Technology, Netherlands ; 2 Eindhoven University of Technology and Philips Research Laboratories Eindhoven, Netherlands ; 3 Eindhoven University of Technology and Kempenhaeghe Epilepsy Center, Netherlands

Keyword(s): Combined EEG-fMRI, Gradient Artefact Correction, Transient Head Movements, Cubic Spline Interpolation.

Related Ontology Subjects/Areas/Topics: Applications and Services ; Biomedical Engineering ; Biomedical Signal Processing ; Computer Vision, Visualization and Computer Graphics ; Detection and Identification ; Electromagnetic Fields in Biology and Medicine ; Informatics in Control, Automation and Robotics ; Medical Image Detection, Acquisition, Analysis and Processing ; Physiological Processes and Bio-Signal Modeling, Non-Linear Dynamics ; Signal Processing, Sensors, Systems Modeling and Control ; Time and Frequency Response ; Time-Frequency Analysis

Abstract: This paper presents a novel approach for removing gradient artefacts from the EEG signal recorded during continuous EEG-fMRI, which are influenced by transient head movements of the subject within the magnetic scanner. Transient head movements provoke abrupt changes in the gradient artefact waveform, in such a way that they compromise the estimation of an artefact waveform to be subtracted and achieve the EEG correction. According to our proposed methodology, a cubic spline waveform is used to model and represent the signal transitions components. This model is then used to change and approximate the shape of the EEG signal as homogeneous data, in order to improve the performance of the gradient artefact correction technique. The proposed approach also makes use of the signal slope adaption (SSD) method, combined with sum-of-sinusoids modelling for correction of the gradient artefact. Our methodology reveals to perform a robust and satisfactory removal of gradient artefacts under the occurrence of abrupt transient head movements. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 34.203.221.104

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
L. Ferreira, J.; Aarts, R. and J. M. Cluitmans, P. (2014). Removal of Gradient Artefacts during Transient Head Movements for Continuous EEG-fMRI. In Proceedings of the International Conference on Bio-inspired Systems and Signal Processing (BIOSTEC 2014) - BIOSIGNALS; ISBN 978-989-758-011-6; ISSN 2184-4305, SciTePress, pages 213-220. DOI: 10.5220/0004802002130220

@conference{biosignals14,
author={José {L. Ferreira}. and Ronald M. Aarts. and Pierre {J. M. Cluitmans}.},
title={Removal of Gradient Artefacts during Transient Head Movements for Continuous EEG-fMRI},
booktitle={Proceedings of the International Conference on Bio-inspired Systems and Signal Processing (BIOSTEC 2014) - BIOSIGNALS},
year={2014},
pages={213-220},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004802002130220},
isbn={978-989-758-011-6},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Bio-inspired Systems and Signal Processing (BIOSTEC 2014) - BIOSIGNALS
TI - Removal of Gradient Artefacts during Transient Head Movements for Continuous EEG-fMRI
SN - 978-989-758-011-6
IS - 2184-4305
AU - L. Ferreira, J.
AU - Aarts, R.
AU - J. M. Cluitmans, P.
PY - 2014
SP - 213
EP - 220
DO - 10.5220/0004802002130220
PB - SciTePress