Cuff-less Calibration-free Blood Pressure Estimation under Ambulatory Environment using Pulse Wave Velocity and Photoplethysmogram Signals

Haruyuki Sanuki, Rui Fukui, Tsukasa Inajima, Shin'ichi Warisawa

2017

Abstract

This paper presents a blood pressure estimation method based on pulse wave velocity (PWV). Although there are a variety of methods based on PWV to estimate blood pressure, most of them require calibration per patient, and the patient has to remain still. The goal of our research is to develop a calibration-free blood pressure estimation method that is applicable not only during rest but also during exercise. To accomplish our goal, we extracted properties of blood vessels from photoplethysmogram (PPG) signals, and compared several regression models, such as the deductive model based on blood vessel physics equation, and the inductive model based on machine learning. Twenty-four participants performed exercise, measuring blood pressure, electrocardiogram (ECG) and PPG. The best result showed that the mean error for the estimated systolic blood pressure (SBP) against cuff-based blood pressure was 0.18 ± 8.68 mmHg. Although there was not a big difference between the regression models, PWV and Augmentation Index are effective features to estimate SBP. In addition to this, Heart Rate was effective only for the young men, and height ratio of c-wave to a-wave of acceleration pulse wave might be effective for elderly men. These results suggest that our proposed method has the potential for cuff-less calibration-free blood pressure estimation which include measurements during rest and exercise.

Download


Paper Citation


in Harvard Style

Sanuki H., Fukui R., Inajima T. and Warisawa S. (2017). Cuff-less Calibration-free Blood Pressure Estimation under Ambulatory Environment using Pulse Wave Velocity and Photoplethysmogram Signals. In - BIOSIGNALS, (BIOSTEC 2017) ISBN , pages 0-0. DOI: 10.5220/0006112500001488


in Bibtex Style

@conference{biosignals17,
author={Haruyuki Sanuki and Rui Fukui and Tsukasa Inajima and Shin'ichi Warisawa},
title={Cuff-less Calibration-free Blood Pressure Estimation under Ambulatory Environment using Pulse Wave Velocity and Photoplethysmogram Signals},
booktitle={ - BIOSIGNALS, (BIOSTEC 2017)},
year={2017},
pages={},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006112500001488},
isbn={},
}


in EndNote Style

TY - CONF

JO - - BIOSIGNALS, (BIOSTEC 2017)
TI - Cuff-less Calibration-free Blood Pressure Estimation under Ambulatory Environment using Pulse Wave Velocity and Photoplethysmogram Signals
SN -
AU - Sanuki H.
AU - Fukui R.
AU - Inajima T.
AU - Warisawa S.
PY - 2017
SP - 0
EP - 0
DO - 10.5220/0006112500001488