Abstract: Two new laser Doppler flowmeter prototypes are herein validated with Monte Carlo simulations. The first prototype is a multi-wavelength laser Doppler flowmeter with different spaced detection fibres that will add depth discrimination capabilities to LDF skin monitoring. The other prototype is a self-mixing based laser Doppler flowmeter for brain perfusion estimation. In order to validate these two prototypes, Monte Carlo simulations are performed. For the first prototype validation, Monte Carlo simulations in a phantom consisting of moving fluid (pumped milk) at six different depths as well as in a skin model are proposed. For this prototype, the results show that the first order moment of the photocurrent power spectrum (M1) and mean depth measured both increase with the fibre distances tested. Moreover, M1 increases with the concentration of milk, whereas the mean depth measured decreases with the milk concentration for the phantom results. Furthermore, we show that increasing the w avelength of incoming light, in the skin model, increases the mean depth probed. For the second prototype validation, Monte Carlo simulations are carried out on a rat brain model. We show that the mean measurement depth in the rat brain with our probe is 0.15 mm. (More)

PDF ImageFull Text

Download
Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 54.224.220.72

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Figueiras E., Campos R., Oliveira R., F. Requicha Ferreira L., de Mul F. and Humeau-Heurtier A. (2012). LASER DOPPLER FLOWMETERS PROTOTYPES VALIDATION USING MONTE CARLO SIMULATIONS.In Proceedings of the International Conference on Bioinformatics Models, Methods and Algorithms - Volume 1: BIOINFORMATICS, (BIOSTEC 2012) ISBN 978-989-8425-90-4, pages 24-33. DOI: 10.5220/0003709100240033

@conference{bioinformatics12,
author={Edite Figueiras and Rita Campos and Ricardo Oliveira and Luís F. Requicha Ferreira and Frits de Mul and Anne Humeau-Heurtier},
title={LASER DOPPLER FLOWMETERS PROTOTYPES VALIDATION USING MONTE CARLO SIMULATIONS},
booktitle={Proceedings of the International Conference on Bioinformatics Models, Methods and Algorithms - Volume 1: BIOINFORMATICS, (BIOSTEC 2012)},
year={2012},
pages={24-33},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003709100240033},
isbn={978-989-8425-90-4},
}

TY - CONF

JO - Proceedings of the International Conference on Bioinformatics Models, Methods and Algorithms - Volume 1: BIOINFORMATICS, (BIOSTEC 2012)
TI - LASER DOPPLER FLOWMETERS PROTOTYPES VALIDATION USING MONTE CARLO SIMULATIONS
SN - 978-989-8425-90-4
AU - Figueiras E.
AU - Campos R.
AU - Oliveira R.
AU - F. Requicha Ferreira L.
AU - de Mul F.
AU - Humeau-Heurtier A.
PY - 2012
SP - 24
EP - 33
DO - 10.5220/0003709100240033

Login or register to post comments.

Comments on this Paper: Be the first to review this paper.